Case Study:
Clean Side Removal Cartridges improved dust release & prolonged life cycle
Location:
- ROMANIA
Operation:
Cement Silo
Dust type:
Cement dust
Problem:
- In 2010 the customer installed Nordic Air Filtration’s Clean Side Removal CKD230 cartridges in his Donaldson Siloair unit, which is situated on the roof of the cement silo.
Solution:
- After replacing the original Donaldson cartridges with Nordic Air Filtration’s CKD230, the customer has experienced a longer life cycle of the filters.
- The cartridges are equipped with NA-909FC filter media which is one of Nordic Air Filtration’s superior polyester medias with PTFE coating. The PTFE coating ensures optimal dedusting and is the optimal solution for concrete dust.
End User’s main areas of business
- Prefabricated concrete
- AAC - Aerated Autoclaved Concrete
TECHNICAL FACTS |
||
CKD230 in Donaldson Siloair Unit | ||
Airflow in unit | 1500 m3/hour | |
Dusttype | Cement | |
Temperature in unit | 80 | |
Actual dust load
|
52 m3/m2/hour | |
Filter model | Clean Side Removal Cartridge CKD230 | |
Filter Media type | Polyester with PTFE coating | |
Number of cartridges | 8 | |
Amount of filter media in unit | 28,8m² |
Advantages:
- Longer filter life cycle
- PTFE-coating for better dust release under humid conditions